SPD01 |
Lightning and surge protection device
that can be plugged directly into the mains and the
equipment that needs to be protected plugs into the
front of the device. To be used with any office or house
hold equipment that runs from the mains such as
Telephone systems, intercoms, washing machines,
Microwave oven etc . |
 |
| |
SPD02 |
Lightning and surge protection for both
mains and telephone lines are incorporated into this
unit. This unit should be used on all modems, fax
machines, cordless telephones and any units that use a
combination of electricity and telecommunications. |
 |
| |
SPD03
Standard Plug |
Lightning and
surge protection built into a standard SABS approved
plug that can be connected to a single device that
requires protection. To be used with any office or house
hold equipment that runs from the mains. |
 |
| |
SPD03D
Dedicated Plug |
Lightning and
surge protection built into a standard SABS approved
plug that can be connected to a single device that
requires protection. To be used with any office or house
hold equipment that runs from the mains. |
 |
| |
SPD06-RM |
As per the
LPD06 this unit should be used to protect the hubs. All
network cables need to be protected on both sides to
prevent damage to the connected equipment. This unit
will protect 12 cables and mounts into a standard 19”
cabinet. |
 |
| |
SPD07 |
Lightning and
surge protection for both mains and data lines are
incorporated into this unit. This unit should be used on
all computers that are connected to a local area
network. |
 |
| |
SPD10 |
Lightning and
surge protection for mains, telephone and data lines are
incorporated into this unit. This unit should be used on
all multi function printers.
|
 |
| |
SPD13 |
Lightning and
surge protection for both mains and television aerial
inputs are incorporated into this unit. This unit should
be used on television sets or decoders that communicate
via radio signals.
|
 |
| |
SPD14 |
Lightning and
surge protection for both mains and Satellite decoder
inputs are incorporated into this unit. This unit should
be used on all satellite decoders. |
 |
| |
SPD15 |
The unit is
designed to protect the LMB inside the dish from spike
or surges induced by lightning. |
 |
| |
SPD16 |
The unit is
designed to protect closed circuit television cameras (CCTV)
from spikes or surges induced by lightning. The units
are installed at each camera between the camera and the
communication cable. |
 |
| |
SPD
Specifications
Power Line
- Operating voltage 220 - 250 V
- Max clamping voltage # 700 V
- Peak impulse current * 6500 A
- Energy absorption 150 J
- Response time 5uS
- Protection modes Common and different mode
protection
- RFI Attenuation 50 dB to-65 dB (Over the range
100 KHz to 50 MHz)
Telephone Line
- DC spark over voltage 230V
- Max clamping voltage # 800V
- Peak impulse current * 10 000A
- Capacitance 35pF
- Lines protected One
Data Line - 1000Base T
- Nominal voltage 8V
- Nominal Discharge Current 300A
- Max Discharge Current 25kA (8/20us)
- Protection Level at 300A 40V
- Response Time < 1ns
- Data Transfer Rate 100 Mbs
- Protective Circuit 2 x twisted pairs
- Series Resistance zero (0) ohms
- Data Socket RJ45
- Earth (protective) 2 Earth wire
CCTV
- Nominal voltage 12 V
- Nominal Discharge Current 8/20us
- Screen & Protected Ground 10 KA
- Line & Screen 5 KA
- Max between screen / ground 20kA
- Protection Level @ 1KV/us 600V
- Frequency Range 20 MHz
- Band Width 75 MHz
- Return Loss 20dB
- Response Time < 1ns
- Connectors Male / Female BNC
- Earth (protective) 1,5mm2 Earth wire
All units are approved by Telkom and SABS |